INT-1948 added support for 'cache-level' attribute to the namespace-based configuration of JMS Message Driven Channel adapter and JMS Inbound Gateway
This commit is contained in:
@@ -111,6 +111,7 @@ public class JmsMessageDrivenChannelAdapterParserTests {
|
||||
AbstractMessageListenerContainer container = (AbstractMessageListenerContainer)
|
||||
new DirectFieldAccessor(gateway).getPropertyValue("listenerContainer");
|
||||
assertEquals(33, new DirectFieldAccessor(container).getPropertyValue("idleConsumerLimit"));
|
||||
assertEquals(3, new DirectFieldAccessor(container).getPropertyValue("cacheLevel"));
|
||||
gateway.stop();
|
||||
}
|
||||
|
||||
|
||||
@@ -8,7 +8,7 @@
|
||||
http://www.springframework.org/schema/integration
|
||||
http://www.springframework.org/schema/integration/spring-integration.xsd
|
||||
http://www.springframework.org/schema/integration/jms
|
||||
http://www.springframework.org/schema/integration/jms/spring-integration-jms.xsd">
|
||||
http://www.springframework.org/schema/integration/jms/spring-integration-jms-2.0.xsd">
|
||||
|
||||
<jms:message-driven-channel-adapter id="adapterWithReceiveTimeout"
|
||||
connection-factory="testConnectionFactory"
|
||||
@@ -32,7 +32,8 @@
|
||||
connection-factory="testConnectionFactory"
|
||||
destination-name="testQueue"
|
||||
idle-consumer-limit="33"
|
||||
auto-startup="false"/>
|
||||
cache-level="3"
|
||||
auto-startup="false" />
|
||||
|
||||
<bean id="testConnectionFactory" class="org.springframework.jms.connection.SingleConnectionFactory">
|
||||
<constructor-arg>
|
||||
|
||||
Reference in New Issue